Model | Swept Analyzer Bandwidth | TG Frequency Range | VNA (S11,S21) Range | DANL | RBW | Touch Screen, Web Control, Mouse/Keyboard Support | Real Time | |
---|---|---|---|---|---|---|---|---|
SSA3000X Series | SSA3021X | 9 kHz - 2.1 GHz | 100 kHz - 2.1 GHz | – | -161 dBm/Hz | 1 Hz - 1 MHz | – | – |
SSA3032X | 9 kHz - 3.2 GHz | 100 kHz - 3.2 GHz | – | -161 dBm/Hz | 1 Hz - 1 MHz | – | – | |
SSA3000X Plus Series | SSA3015X Plus | 9 kHz - 1.5 GHz | 100 kHz - 1.5 GHz | – | -156 dBm/Hz | 1 Hz - 1 MHz | Included | – |
SSA3021X Plus | 9 kHz - 2.1 GHz | 100 kHz - 2.1 GHz | – | -161 dBm/Hz | 1 Hz - 1 MHz | Included | – | |
SSA3032X Plus | 9 kHz - 3.2 GHz | 100 kHz - 3.2 GHz | – | -161 dBm/Hz | 1 Hz - 1 MHz | Included | – | |
SSA3075X Plus | 9 kHz - 7.5 GHz | 100 kHz - 7.5 GHz | – | -165 dBm/Hz | 1 Hz - 3 MHz | Included | – | |
SVA1000X Series | SVA1015X | 9 kHz - 1.5 GHz | 100 kHz - 1.5 GHz | 100 kHz-1.5 GHz | -156 dBm/Hz | 1 Hz - 1 MHz | Included | – |
SVA1032X | 9 kHz - 3.2 GHz | 100 kHz - 3.2 GHz | 100 kHz-3.2 GHz | -161 dBm/Hz | 1 Hz - 1 MHz | Included | – | |
SVA1075X | 9 kHz - 7.5 GHz | 100 kHz - 7.5 GHz | 100 kHz-7.5 GHz | -165 dBm/Hz | 1 Hz - 3 MHz | Included | – | |
SSA3000X-R Series | SSA3032X-R | 9 kHz - 3.2 GHz | 100 kHz - 3.2 GHz | 100 kHz-3.2 GHz | -165 dBm/Hz | 1 Hz - 3 MHz | Included | Included |
SSA3050X-R | 9 kHz - 5 GHz | 100 kHz - 5 GHz | 100 kHz-5 GHz | -165 dBm/Hz | 1 Hz - 3 MHz | Included | Included | |
SSA3075X-R | 9 kHz - 7.5 GHz | 100 kHz - 7.5 GHz | 100 kHz-7.5 GHz | -165 dBm/Hz | 1 Hz - 3 MHz | Included | Included | |
SSA5000A Series | SSA5083A | 9 kHz - 13.6 GHz | - | - | -165 dBm/Hz | 1 Hz - 10 MHz | Included | 25 MHz (option), 40 MHz (option) |
SSA5085A | 9 kHz - 26.5 GHz | - | - | -165 dBm/Hz | 1 Hz - 10 MHz | Included | 25 MHz (option), 40 MHz (option) |
SIGLENT Analyzer Options:
Model | Swept Analyzer Bandwidth | Options | AMK details | Digital Modulation (DMA option) details | EMI Option details | |
---|---|---|---|---|---|---|
SSA3000X Series | SSA3021X | 9 kHz - 2.1 GHz | AMK, EMI, REFL (1) | CHP/ACPR/TOI/OBW/Monitor | – | 200 Hz,9 kHz,120 kHz |
SSA3032X | 9 kHz - 3.2 GHz | AMK, EMI, REFL (1) | CHP/ACPR/TOI/OBW/Monitor | – | 200 Hz,9 kHz,120 kHz | |
SSA3000X Plus Series | SSA3015X Plus | 9 kHz - 1.5 GHz | AMK, EMI, REFL, AMA, DMA (2) | CHP/ACPR/TOI/OBW/Monitor/Harmonic/CNR | ASK/FSK/PSK/QAM | 200 Hz,9 kHz,120 kHz,1 MHz |
SSA3021X Plus | 9 kHz - 2.1 GHz | AMK, EMI, REFL, AMA, DMA (2) | CHP/ACPR/TOI/OBW/Monitor/Harmonic/CNR | ASK/FSK/PSK/QAM | 200 Hz,9 kHz,120 kHz,1 MHz | |
SSA3032X Plus | 9 kHz - 3.2 GHz | AMK, EMI, REFL, AMA, DMA (2) | CHP/ACPR/TOI/OBW/Monitor/Harmonic/CNR | ASK/FSK/PSK/QAM | 200 Hz,9 kHz,120 kHz,1 MHz | |
SSA3075X Plus | 9 kHz - 7.5 GHz | AMK, EMI, REFL, AMA, DMA (2) | CHP/ACPR/TOI/OBW/Monitor/Harmonic/CNR | ASK/FSK/PSK/QAM | 200 Hz,9 kHz,120 kHz,1 MHz | |
SVA1000X Series | SVA1015X | 9 kHz - 1.5 GHz | AMK, EMI, REFL, AMA, DMA (3) | CHP/ACPR/TOI/OBW/Monitor/Harmonic/CNR | ASK/FSK/PSK/QAM | 200 Hz,9 kHz,120 kHz,1 MHz |
SVA1032X | 9 kHz - 3.2 GHz | AMK, EMI, REFL, AMA, DMA (3) | CHP/ACPR/TOI/OBW/Monitor/Harmonic/CNR | ASK/FSK/PSK/QAM | 200 Hz,9 kHz,120 kHz,1 MHz | |
SVA1075X | 9 kHz - 7.5 GHz | AMK, EMI, REFL, AMA, DMA (3) | CHP/ACPR/TOI/OBW/Monitor/Harmonic/CNR | ASK/FSK/PSK/QAM | 200 Hz,9 kHz,120 kHz,1 MHz | |
SSA3000X-R Series | SSA3032X-R | 9 kHz - 3.2 GHz | AMK, EMI, REFL, AMA, DMA (4) | CHP/ACPR/TOI/OBW/Monitor/Harmonic/CNR | ASK/FSK/PSK/QAM | 200 Hz,9 kHz,120 kHz,1 MHz |
SSA3050X-R | 9 kHz - 5 GHz | AMK, EMI, REFL, AMA, DMA (4) | CHP/ACPR/TOI/OBW/Monitor/Harmonic/CNR | ASK/FSK/PSK/QAM | 200 Hz,9 kHz,120 kHz,1 MHz | |
SSA3075X-R | 9 kHz - 7.5 GHz | AMK, EMI, REFL, AMA, DMA (4) | CHP/ACPR/TOI/OBW/Monitor/Harmonic/CNR | ASK/FSK/PSK/QAM | 200 Hz,9 kHz,120 kHz,1 MHz | |
SSA5000A Series | SSA5083A | 9 kHz - 13.6 GHz | AMK, Preamplifier, OCXO, Real time (25 MHz), Real time (40 MHz), upgrade to 26.5 GHz | CHP/ACPR/TOI/OBW/Monitor/Harmonic/CNR | - | - |
SSA5085A | 9 kHz - 26.5 GHz | AMK, Preamplifier, OCXO, Real time (25 MHz), Real time (40 MHz) | CHP/ACPR/TOI/OBW/Monitor/Harmonic/CNR | - | - |
Tracking Generator included free with all SSA3000X, Plus, SVA, and X-R series analyzers
1- SSA3000X options
AMK – Advanced measurement kit
EMI – Electromagnetic Precompliance option
REFL- VSWR/Reflection coefficient measurement option requires an external return loss bridge or coupler like SIGLENT RB3X25
2- SSA3000X Plus options
AMK – Advanced measurement kit
EMI – Electromagnetic Precompliance option
REFL- VSWR/Reflection coefficient measurement option requires an external return loss bridge or coupler like SIGLENT RB3X25
AMA- Analog Modulation Analysis
DMA- Digital Modulation Analysis
3- SVA1000X Options
AMK – Advanced measurement kit
EMI – Electromagnetic Precompliance option
AMA- Analog Modulation Analysis
DMA- Digital Modulation Analysis
4- SSA3000X-R Options
AMK – Advanced measurement kit
EMI – Electromagnetic Precompliance option
AMA- Analog Modulation Analysis
DMA- Digital Modulation Analysis